VALVE
NOT WORKING
Problem:
- Water
running to drain
- Brine
tank overflowing
- Motor
stalled
- Water
leaking from valve
Solution:
1.
Before you start to service a valve, make sure it is in the service
position. Place bypass valve in bypass to shut off water. Loosen
3 of 5 hex screws at top back of valve. This will relieve pressure
in the softener.
2.
If water is running to drain in service, if brine tank is overflowing,
or the motor is not turning the valve (valve stuck):
-
Remove
the 5 hex screws from the top of the valve and carefully remove
the cover.
-
Replace
the seal kit parts #9 through #12. Be sure wear strip (#9)
is placed on top of rubber seal (#10).
-
Inspect
the rotor for wear, scratches or cracks, and replace if needed.
-
Check
all o-rings for wear, cuts, flat spots, proper positioning,
etc., and replace as needed.
-
Install
the valve cover and 5 screws.
3.
Turn the water on and check to see if failure is corrected.
4.
If water is leaking from the top of the valve, or between #3 and
#14, replace o-rings 4, 5 and 8. Turn water on and check again
for leaks.
5.
If the brine tank is overfilling, with little or no water flow
from the valve drain hose during regeneration, check flow plug
#1, drain elbow #2, and the valve drain hose for obstruction.
|
|