View the Windsor System Saver Video! System Saver Home Page Visit Windsor Salt Online Common Water Terms Frequently Asked Questions About Water Softeners System Saver Site Index Contact Us
Windsor System Saver Water Softeners

Troubleshooting Guide
NO BRINE DRAW
Valve Not Working
Salt Bridge

MAINTENANCE
TROUBLESHOOTING
PARTS OF A WATER SOFTENER
VIEW  VIDEO

No Brine Draw

Problem:

  • Brine tank full of water
  • No soft water
  • Not using salt

Solution:

1. Use the following steps to disassemble and clean the nozzle and venturi.

  • Clean all parts using a soft tooth brush, mild soap and warm water. Use resin bed cleaner if parts are iron coated. Rinse with clean fresh water. Do not use any sharp or hard objects to clean bottom of item #6.
  • Remove parts 1-7, 9 and 10. Set parts aside and clean.
  • Reinstall cap (#1) and o-ring (#2).
Water Softener Troubleshooting
Water Facts, Water Testing, Water Softener Benefits, How Softeners Work
System Saver Product List, Product Specifications, Selection Assistance, Parts & Accessories, Product Manuals
Maintenance and Troubleshooting Tips
Installation Help, Plumbing Basics, System Requirements
Questions? Call the System Saver Help Line! 888-64-WATER, (888-649-2837)
2. Lift the brine valve assembly (#13) from the brinewell.
  • Remove the plastic clip (#12) and pull the asembly apart.
  • Use the SELECT or TOUCH HOLD button to enter the unit into a manual regeneration and advance the valve to the fill position.
  • As the valve advances into FILL, there will be a flow of water from the tubing. Use this to wash down the brine valve assembly of any excess salt. Also wash down the brine well of excess salt.
  • Move t he bypass valve into BYPASS to shut off the flow of water to the valve.
  • Use the toothbrush to thoroughly clean the nozzle and venturi (#6), flow plugs (#5 and #9) and screens (#4, #10 and #11). Carefully clean the flow plug center hole with a small wire.
  • Reassemble all parts in the nozzle venturi. BE SURE #& is installed correctly, numbers up on the flow plugs (#5 and #9).
Click On Picture for Larger View.
  • Advance the valve into the BRINE position. Place the BYPASS valve into service and check for suction on the tubing that connects to the BRINE VALVE ASSEMBLY. If not, recheck the assembly of the nozzle venturi. If still no suction see "VALVE NOT WORKING."
  • If suction is now working, reinstall the BRINE VALVE ASSEMBLY and finish the regeneration.